Pasadena Power voltage "brown out"  12/31/02
Data via mauisolarsoftware.com TraceTools application monitoring Trace inverter
Visible sign of problem when lights in house brightened as voltage increased because
intervter sensed the low grid voltage and switched off grid to battery provided power.
Time Grid_ Grid_ Grid_ Inv_ Inv_ Inv_ Batt_ Batt_ Batt_ Load_ Load_ Load_
Amps Volts W Amps Volts W Amps Volts W Amps Volts W
17:12 15 111 1676 15 110 1650 -0.33 54.52 -36 14 110 1595
17:13 14 112 1577 14 110 1553 -0.75 54.37 -82 14 110 1636
17:14 7 112 849 7 110 834 6.92 52.40 760 14 110 1622
17:15 0 111 0 0 118 0 14.00 49.43 1652 14 118 1760
17:16 0 95 0 0 119 0 14.00 49.32 1666 15 119 1785
17:17 0 79 0 0 119 0 14.00 49.20 1666 15 119 1785
17:18 0 82 0 0 119 0 12.67 49.33 1507 13 119 1626
17:19 8 114 958 8 119 970 5.83 50.68 699 14 119 1698
17:20 23 110 2595 23 109 2540 -9.23 54.37 -1010 14 109 1555
17:21 18 112 2044 18 109 1999 -5.25 54.32 -575 14 109 1534
17:22 17 111 1980 17 109 1947 -3.42 54.42 -372 15 109 1637